{"id":807,"date":"2024-03-01T00:00:00","date_gmt":"2024-02-29T21:00:00","guid":{"rendered":"https:\/\/www.fibacloud.com\/tr\/kaynaklar\/?p=807"},"modified":"2026-10-06T02:41:35","modified_gmt":"2026-10-05T23:41:35","slug":"vrealize-operations-manager-nedir","status":"publish","type":"post","link":"https:\/\/www.fibacloud.com\/tr\/kaynaklar\/bulut-danismanlik-hizmeti\/vrealize-operations-manager-nedir\/","title":{"rendered":"vRealize Operations Manager (vROPS) Nedir?"},"content":{"rendered":"<div class=\"fc-resource-revision\" data-fc-editorial=\"20261006\">\n<p class=\"fc-article-summary\">vRealize Operations Manager, yayg\u0131n k\u0131saltmas\u0131yla vROPS, sanalla\u015ft\u0131r\u0131lm\u0131\u015f altyap\u0131daki kaynak ve performans verilerini bir araya getirerek i\u015fletim kararlar\u0131n\u0131 destekleyen \u00fcr\u00fcn ailesinin tarihsel adlar\u0131ndan biridir. Bu rehber, kavram\u0131 ve kullan\u0131m mant\u0131\u011f\u0131n\u0131 a\u00e7\u0131klar. Kurulum veya y\u00fckseltme i\u00e7in mevcut \u00fcr\u00fcn ad\u0131, s\u00fcr\u00fcm ve hak sahipli\u011fi Broadcom belgeleri \u00fczerinden ayr\u0131ca e\u015fle\u015ftirilmelidir.<\/p>\n<figure class=\"fc-editorial-figure\"><img loading=\"lazy\" src=\"\/community\/assets\/resource-renewal-20261006\/vrops-operations-tr.svg\" width=\"960\" height=\"440\"  decoding=\"async\" alt=\"Altyap\u0131 ve adapt\u00f6rlerden metrik toplan\u0131r; g\u00fcncellik ve ba\u011flam kontrol edilir. Kapasite e\u011filimi veya alarm operat\u00f6re bir inceleme nedeni sunar. Operat\u00f6r \u00f6l\u00e7\u00fcm\u00fc do\u011frular, de\u011fi\u015fikli\u011fi de\u011ferlendirir ve sonucu izler.\"><figcaption>Bir \u00f6neri, do\u011frulanm\u0131\u015f neden veya uygulanmas\u0131 zorunlu bir de\u011fi\u015fiklik de\u011fildir.<br \/><a class=\"fc-diagram-open\" href=\"\/community\/assets\/resource-renewal-20261006\/vrops-operations-tr.svg\">G\u00f6rseli b\u00fcy\u00fct \u2192<\/a><\/figcaption><\/figure>\n<h2>\u0130\u015fletim analiti\u011fi ne sa\u011flar?<\/h2>\n<p>Tek bir sunucunun CPU y\u00fczdesi \u00e7o\u011fu zaman sorunun tamam\u0131n\u0131 anlatmaz. Bir sanal makine, ana sistem, veri deposu ve uygulama ayn\u0131 olaya farkl\u0131 g\u00f6stergelerle tepki verebilir. \u0130\u015fletim analiti\u011fi bu ili\u015fkileri g\u00f6r\u00fcn\u00fcr k\u0131lmaya yard\u0131mc\u0131 olur. Ama\u00e7 \u00e7ok say\u0131da grafik \u00fcretmekten \u00f6nce, sorunun hangi katmanda ara\u015ft\u0131r\u0131laca\u011f\u0131n\u0131 belirlemektir.<\/p>\n<p>Metrik, g\u00fcnl\u00fck ve uygulama izi farkl\u0131 veri t\u00fcrleridir. Kaynak kullan\u0131m e\u011filimi kapasite planlamas\u0131na katk\u0131 sa\u011flarken bir hatan\u0131n tam i\u00e7eri\u011fi uygulama g\u00fcnl\u00fc\u011f\u00fcnde bulunabilir. Her veri t\u00fcr\u00fcn\u00fcn ayn\u0131 \u00fcr\u00fcn lisans\u0131nda veya her adapt\u00f6rle sa\u011fland\u0131\u011f\u0131n\u0131 varsaymay\u0131n. Gereken g\u00f6r\u00fcn\u00fcrl\u00fc\u011f\u00fc somut kullan\u0131m senaryosundan \u00e7\u0131kar\u0131n.<\/p>\n<h2>Kurulu s\u00fcr\u00fcm\u00fc ve entegrasyonlar\u0131 tan\u0131y\u0131n<\/h2>\n<p>vROPS ve vRealize adlar\u0131 eski kurulumlarda ve arama sonu\u00e7lar\u0131nda g\u00f6r\u00fclebilir. \u00dcr\u00fcn ailesinin farkl\u0131 d\u00f6nemlerdeki adlar\u0131, paketleri ve belgeleri birbirine kar\u0131\u015ft\u0131r\u0131lmamal\u0131d\u0131r. Y\u00f6netim ekran\u0131ndan kurulu s\u00fcr\u00fcm\u00fc belirleyin; desteklenen altyap\u0131 s\u00fcr\u00fcmleri, adapt\u00f6rler ve y\u00fckseltme yolu i\u00e7in buna ait resm\u00ee belgeyi kullan\u0131n.<\/p>\n<p>Toplama hesab\u0131n\u0131n hangi envanteri g\u00f6rebildi\u011fini ve hangi yetkilere sahip oldu\u011funu kontrol edin. Gere\u011finden geni\u015f bir hesap g\u00fcvenlik riskini art\u0131rabilir; eksik izinler ise g\u00f6r\u00fcnmeyen kaynaklara yol a\u00e7abilir. Adapt\u00f6r\u00fcn \u00e7al\u0131\u015f\u0131yor g\u00f6r\u00fcnmesi b\u00fct\u00fcn verilerin g\u00fcncel ve tam oldu\u011funu g\u00f6stermez. Son ba\u015far\u0131l\u0131 toplama zaman\u0131 ve eksik nesneler ayr\u0131ca incelenmelidir.<\/p>\n<h2>Kapasite e\u011filimini nas\u0131l yorumlamal\u0131?<\/h2>\n<p>Kapasite \u00f6nerisi, ge\u00e7mi\u015f kullan\u0131m ve se\u00e7ilen politika \u00fczerinden \u00fcretilir. \u0130\u015f y\u00fck\u00fcn\u00fcn mevsimselli\u011fi, planlanan kampanya veya yeni bir uygulama s\u00fcr\u00fcm\u00fc ge\u00e7mi\u015fte g\u00f6r\u00fcnmeyebilir. Bu nedenle \u00f6nerilen k\u00fc\u00e7\u00fcltme veya b\u00fcy\u00fctme, i\u015f sahibinin beklentisiyle birlikte de\u011ferlendirilmelidir. G\u00fcnl\u00fck ortalama, k\u0131sa ama kritik yo\u011funluklar\u0131 gizleyebilir.<\/p>\n<p>\u00d6rne\u011fin bir veritaban\u0131nda d\u00fc\u015f\u00fck CPU kullan\u0131m\u0131 bo\u015f kaynak oldu\u011fu anlam\u0131na gelmeyebilir; uygulama disk veya kilit bekliyor olabilir. Ayn\u0131 d\u00f6nemin gecikme, bellek ve depolama \u00f6l\u00e7\u00fcmlerini inceleyin. Kapasite de\u011ferlendirmesinin ba\u015far\u0131 \u00f6l\u00e7\u00fct\u00fc yaln\u0131z kaynak y\u00fczdesi de\u011fil, uygulaman\u0131n gereken i\u015fi kabul edilebilir s\u00fcrede tamamlamas\u0131d\u0131r.<\/p>\n<h2>Alarm\u0131 uygulanabilir hale getirin<\/h2>\n<ol>\n<li>Alarm\u0131n hangi ko\u015fulla olu\u015ftu\u011funu ve hangi kaynaklar\u0131 kapsad\u0131\u011f\u0131n\u0131 anlay\u0131n.<\/li>\n<li>Uyar\u0131y\u0131 ilgili uygulama sahibi ve bak\u0131m takvimiyle ili\u015fkilendirin.<\/li>\n<li>Yanl\u0131\u015f pozitifleri inceleyin; sessize alma i\u015flemlerine s\u00fcre ve gerek\u00e7e ekleyin.<\/li>\n<li>Kritik alarmlar i\u00e7in inceleme, y\u00fckseltme ve kapan\u0131\u015f sorumlusu belirleyin.<\/li>\n<li>De\u011fi\u015fiklikten sonra hem metri\u011fi hem kullan\u0131c\u0131ya yans\u0131yan sonucu kontrol edin.<\/li>\n<\/ol>\n<p>Her \u00f6neriyi otomatik uygulamak uygun olmayabilir. Bellek k\u00fc\u00e7\u00fcltme, i\u015f y\u00fck\u00fc ta\u015f\u0131ma veya kaynak politikas\u0131 de\u011fi\u015fikli\u011fi uygulamay\u0131 etkileyebilir. Otomasyon kullan\u0131lacaksa ilgili \u00fcr\u00fcn s\u00fcr\u00fcm\u00fcn\u00fcn yetenekleri, onay s\u0131n\u0131rlar\u0131 ve geri d\u00f6n\u00fc\u015f s\u00fcreci a\u00e7\u0131k olmal\u0131d\u0131r.<\/p>\n<h2>Fayday\u0131 nas\u0131l \u00f6l\u00e7ersiniz?<\/h2>\n<p>\u00d6nce \u00e7\u00f6z\u00fclmek istenen i\u015fletim problemini se\u00e7in: kapasite s\u00fcrprizleri, uzun inceleme s\u00fcresi veya sahipsiz alarmlar gibi. Ard\u0131ndan ba\u015flang\u0131\u00e7 durumunu ve izlenecek sonucu tan\u0131mlay\u0131n. Toplama bo\u015fluklar\u0131n\u0131n azalmas\u0131, bir olay\u0131n do\u011fru ekibe ula\u015fmas\u0131 ve de\u011fi\u015fiklik sonras\u0131 uygulama davran\u0131\u015f\u0131n\u0131n do\u011frulanmas\u0131, yaln\u0131z pano say\u0131s\u0131ndan daha anlaml\u0131 ilerleme g\u00f6stergeleridir.<\/p>\n<h2>S\u0131k sorulan sorular<\/h2>\n<dl>\n<dt><strong>vROPS uygulaman\u0131n b\u00fct\u00fcn hatalar\u0131n\u0131 bulur mu?<\/strong><\/dt>\n<dd>\n<p>Hay\u0131r. G\u00f6r\u00fcn\u00fcrl\u00fck toplanan veriye, entegrasyonlara ve uygulaman\u0131n g\u00f6zlemlenebilirli\u011fine ba\u011fl\u0131d\u0131r. Metrikler gerekti\u011finde g\u00fcnl\u00fck ve uygulama incelemesiyle tamamlan\u0131r.<\/p>\n<\/dd>\n<dt><strong>Kapasite \u00f6nerisi do\u011frudan uygulanmal\u0131 m\u0131?<\/strong><\/dt>\n<dd>\n<p>\u00d6nce i\u015f y\u00fck\u00fc ba\u011flam\u0131, yo\u011fun d\u00f6nemler ve ba\u011f\u0131ml\u0131l\u0131klar kontrol edilmelidir. \u00dcretim de\u011fi\u015fikli\u011fi i\u00e7in test, onay s\u0131n\u0131r\u0131 ve geri d\u00f6n\u00fc\u015f plan\u0131 gerekir.<\/p>\n<\/dd>\n<\/dl>\n<h2>Sonraki ad\u0131m<\/h2>\n<p><a href=\"https:\/\/www.fibacloud.com\/tr\/kaynaklar\/guvenlik\/vmware-log-insight-nedir\/\">Log Insight rehberi<\/a> ile metrik ve g\u00fcnl\u00fck g\u00f6revlerini ay\u0131r\u0131n. <a href=\"https:\/\/www.fibacloud.com\/tr\/kaynaklar\/bilgi-islem\/vmware-vrealize-automation-nedir\/\">Otomasyon rehberi<\/a> ile onay ve ya\u015fam d\u00f6ng\u00fcs\u00fc s\u0131n\u0131r\u0131n\u0131 belirleyin; uygulama ayr\u0131nt\u0131lar\u0131n\u0131 kurulu s\u00fcr\u00fcm\u00fcn belgesinden do\u011frulay\u0131n.<\/p>\n<h2>Kaynaklar<\/h2>\n<ol>\n<li><a href=\"https:\/\/techdocs.broadcom.com\/us\/en\/vmware-cis\/aria\/aria-operations\/8-18\/vmware-aria-operations-user-guide-8-18.html\" rel=\"noopener\" target=\"_blank\">Broadcom \u2014 VMware Aria Operations 8.18 User Guide<\/a><\/li>\n<li><a href=\"https:\/\/csrc.nist.gov\/pubs\/sp\/800\/137\/final\" rel=\"noopener\" target=\"_blank\">NIST SP 800-137 \u2014 Information Security Continuous Monitoring<\/a><\/li>\n<li><a href=\"https:\/\/nvlpubs.nist.gov\/nistpubs\/Legacy\/SP\/nistspecialpublication800-146.pdf\" rel=\"noopener\" target=\"_blank\">NIST SP 800-146 \u2014 Cloud Computing Synopsis and Recommendations<\/a><\/li>\n<li><a href=\"https:\/\/techdocs.broadcom.com\/us\/en\/vmware-cis\/vcf\/vcf-9-0-and-later\/9-1\/cost-and-capacity-management.html\" rel=\"noopener\" target=\"_blank\">Broadcom \u2014 VCF 9.1 cost and capacity management<\/a><\/li>\n<li><a href=\"https:\/\/techdocs.broadcom.com\/us\/en\/vmware-cis\/aria\/aria-operations\/8-18\/vmware-aria-operations-818-release-notes.html\" rel=\"noopener\" target=\"_blank\">Broadcom \u2014 Aria Operations 8.18 release notes and earlier vRealize version context<\/a><\/li>\n<\/ol>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>vRealize Operations Manager, yayg\u0131n k\u0131saltmas\u0131yla vROPS, sanalla\u015ft\u0131r\u0131lm\u0131\u015f altyap\u0131daki kaynak ve performans verilerini bir araya getirerek i\u015fletim kararlar\u0131n\u0131 destekleyen \u00fcr\u00fcn ailesinin tarihsel adlar\u0131ndan biridir. Bu rehber, kavram\u0131 ve kullan\u0131m mant\u0131\u011f\u0131n\u0131 a\u00e7\u0131klar. Kurulum veya y\u00fckseltme i\u00e7in mevcut \u00fcr\u00fcn ad\u0131, s\u00fcr\u00fcm ve hak sahipli\u011fi Broadcom belgeleri \u00fczerinden ayr\u0131ca e\u015fle\u015ftirilmelidir. Bir \u00f6neri, do\u011frulanm\u0131\u015f neden veya uygulanmas\u0131 zorunlu bir de\u011fi\u015fiklik [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":1384,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[24,26,25,31],"tags":[115,122,99,120,121],"class_list":["post-807","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bulut-danismanlik-hizmeti","category-bilgi-islem","category-buluta-genel-bakis","category-guvenlik","tag-izleme","tag-monitoring","tag-vmware","tag-vrealize-operations-manager","tag-vrops"],"_links":{"self":[{"href":"https:\/\/www.fibacloud.com\/tr\/kaynaklar\/wp-json\/wp\/v2\/posts\/807","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fibacloud.com\/tr\/kaynaklar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.fibacloud.com\/tr\/kaynaklar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.fibacloud.com\/tr\/kaynaklar\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fibacloud.com\/tr\/kaynaklar\/wp-json\/wp\/v2\/comments?post=807"}],"version-history":[{"count":6,"href":"https:\/\/www.fibacloud.com\/tr\/kaynaklar\/wp-json\/wp\/v2\/posts\/807\/revisions"}],"predecessor-version":[{"id":823,"href":"https:\/\/www.fibacloud.com\/tr\/kaynaklar\/wp-json\/wp\/v2\/posts\/807\/revisions\/823"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fibacloud.com\/tr\/kaynaklar\/wp-json\/wp\/v2\/media\/1384"}],"wp:attachment":[{"href":"https:\/\/www.fibacloud.com\/tr\/kaynaklar\/wp-json\/wp\/v2\/media?parent=807"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.fibacloud.com\/tr\/kaynaklar\/wp-json\/wp\/v2\/categories?post=807"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.fibacloud.com\/tr\/kaynaklar\/wp-json\/wp\/v2\/tags?post=807"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}